| Applicable Models | ☑ AG10 ☑ AG20 ☑ AR10 ☑ AR20 ☑ AC10 ☑ AC15 ☑ AC25 ☑ AX11 ☑ AX21 ☑ AX30 ☐ AB11 ☐ AB12 |
| Firmware Version | AG10 / AG20 / AR10 / AR20 / AX11 / AX21 / AX30: Ver. 3.2.0 or later AC10 / AC15 / AC25: Ver. 3.1.1 or later |
This article explains how to restore amnimo edge gateways and routers to their factory settings (initialize them).
🚨 Note: This operation differs from “Initialize Configuration Information.” All types of records, including configuration information, will be deleted.
To initialize only the configuration information, see the following FAQ.
Difference from “Initialize Configuration Information”
When you restore the device to its factory settings, the following items are also initialized in addition to the configuration information.
| Item | Initialize Configuration Information | Restore Factory Settings (Initialize) |
|---|---|---|
| amnimo configuration information | ✔ | ✔ |
| rootfs (including user-installed applications on Ubuntu-based devices) | - | ✔ |
| syslog | - | ✔ |
| amlog | - | ✔ |
| Command history | - | ✔ |
Under /mnt/share (including NxWitness data) |
- | ✔ |
| SSD (SSD-equipped devices only) | - | ✔ |
| Fail-safe counter | - | ✔ |
Procedure
To restore the device to its factory settings, a full firmware update (both sides) is required.
- From the side menu, go to
Administration-Firmware. -
Select
Area Update (Full Update), configure the settings as follows, and perform the firmware update.- Update area:
Both sides - Factory initialization:
Enabled - Firmware update method: Select any method
- Update area:
- After restarting, the device will be restored to its factory settings.
You can also perform this operation using the CLI. For details, see the following manual.
- CLI User's Manual: 2.4.4 Updating the Firmware