| Applicable Models | ☑ AG10 ☑ AG20 ☑ AR10 ☑ AR20 ☑ AC10 ☑ AC15 ☑ AC25 ☑ AX11 ☑ AX21 ☑ AX30 ☐ AB11 ☐ AB12 |
| Firmware Version | N/A |
This article explains how to initialize only the amnimo configuration information. Unlike “Restore to Factory Defaults (Initialize),” rootfs, logs, SSDs, and other items are not initialized.
This procedure initializes the configuration information for this product. There are two methods: using the switch on the device and using the CLI.
⚠ Note: This operation does not “Restore to Factory Defaults (Initialize)” the device. It only initializes the configuration information.
To restore the device to its factory default state, see the following FAQ.
The following restrictions apply when using an AI edge gateway or edge gateway equipped with an SSD.
- The storage settings at the time of product shipment include settings for mounting the SSD.
- Initializing the configuration information deletes these storage settings. After initialization, configure the storage settings to mount the SSD again.
For instructions on saving the settings, see the following manuals.
Differences from “Restore to Factory Defaults (Initialize)”
| Target | Initialize Configuration Information | Restore to Factory Defaults (Initialize) |
|---|---|---|
| amnimo configuration information | ✔ | ✔ |
| rootfs (including user-installed applications on Ubuntu-based devices) | ✔ | |
| syslog | ✔ | |
| amlog | ✔ | |
| Command history | ✔ | |
| Under /mnt/share (including Nx Witness data) | ✔ | |
| SSD (only on devices equipped with an SSD) | ✔ | |
| Fail-safe counter | ✔ |
❶ Procedure Using the Switch on the Device
-
Set the DIP switch on the front of the device to “U-Boot command mode.”
* No operation is required for the AC Series.
-
When the device starts up, press and hold the PUSH switch for at least 3 seconds. The configuration information is initialized.
* For the AC10, press and hold the PUSH switch (SW) on the back until the MOB and ANT LEDs on the top of the device flash simultaneously.
Example for AG10: The switch labeled “SW” (red box) to the right of the CONFIG port on the front of the device.
Example for AG20: The area outlined in red in the figure is the PUSH switch (SW).
Example for AC10: The switch labeled “SW” (red box) between the SIM0 and SIM1 slots on the back of the device.
Example for AC25: The area outlined in red in the figure is the PUSH switch (SW).
-
When only the PWR LED is lit, save the settings.
⚠ Note: The configuration files stored on the device are not initialized. If you restart the device after this operation without writing to the configuration files, it will start with the settings from before initialization.
For instructions on saving the settings, see the following manuals.
Reference Video
❷ Procedure Using the CLI
The command input and output are the same in administrator mode and configuration mode. The following is an example executed in administrator mode.
-
Enter the command to initialize the configuration information.
amnimo# config initialize
-
A message asking whether it is OK to overwrite the settings is displayed. To proceed with initialization, enter
yand press Enter.Do you want to initialize the settings? (y/n):
-
After processing proceeds, a message asking whether to save the settings and restart the device is displayed. Enter
yand press Enter to start the restart. The device starts with the configuration information initialized.Would you like to save settings and reboot the system? (y/n):
-
After startup, begin by setting the password.
Need to register for a new password. Enter password for admin. Enter new password: ← Enter a new password and press Enter Retype new password: ← Enter the new password again and press Enter passwd: password updated successfully.
Appendix: Initializing Nx Witness Settings
The operations above do not initialize the Nx Witness server settings installed on the AG10 / AG20. To also initialize the Nx Witness server settings, perform the following procedure.
STEP 1 Change the Password in the Nx Witness Settings
When working in the GUI
- Open Nx Witness Settings from Advanced Settings and Control in the sidebar.
-
Change the password to
adminand click Save Current Settings to Device.
When working in the CLI
-
Enter amsh mode using the
amshcommand. -
Enter administrator mode using the
enablecommand. -
Enter configuration mode using the
configurecommand. -
Enter
nxwitnessto enter nxwitness configuration mode, and enterpassword. - When prompted to enter the password, enter
admin. When prompted to enter it again, enter the same password. -
Run the
config file savecommand to save the settings.
admin@amnimo:~$ amsh amnimo$ enable password: amnimo# amnimo# configure amnimo(cfg)#
amnimo(cfg)# nxwitness amnimo(cfg-nxwitness)# password Enter new password: ← Enter the password (admin) and press Enter Retype new password: ← Enter the password (admin) and press Enter amnimo(cfg-nxwitness)# exit amnimo(cfg)# exit amnimo# config file save
🚨 Note: Be sure to change the password to admin and save it. Initialization will not be performed correctly with a different password.
STEP 2 Perform a Full Firmware Update (Both Sides)
🚨 Note: This operation returns the device to its initial state and deletes the Nx Witness server settings. After completing the operation, configure the Nx Witness server again from the beginning.
When performing a full update from the Device Management System
Refer to the manual below and perform a full update (both sides). Select Both Sides Update from the firmware update procedure.
- “Device Management System Manual”: Firmware - Firmware Update Procedure
When performing a full update from the GUI
Refer to the manual below and perform a full update (both sides). Select Both Sides for the update area.
- “GUI User's Manual”: Update the Entire Firmware
Comments